39 days left. Time to give this place some juice, the electric kind. I had never done this before, and I was extremely excited. Eddie said nobody touch anything, so naturally, I touched everything.
Outlet boxes
Code says no spot on the wall can be more than six feet from an outlet. Why six? That's how long a lamp cord is. The two little tabs on the box are supposed to rest on the front of the stud. I nailed mine beside it, so the boxes sat too far back and bent. Taking them back out was not easy, so I went back for more boxes and did the rest the right way.
Getting power from the house
The cable feeds the office's whole breaker box, so no indoor wire, and no, you can't bury an extension cord. You need cable rated to be buried. Ours was four fat aluminum wires twisted together: two hots, a neutral and a ground, over an inch thick.
Bury that cable by itself and code says 24 inches. Put it inside gray schedule 40 PVC conduit and you only need 18, measured to the top of the pipe, not the bottom of the trench. Six inches less digging. Sold.
Digging was the easy part. 50 feet of that cable was about $230, they cut it at the store, and once it's cut, it's yours. So we measured that yard like our money depended on it, because it did. 50 feet weighs about 33 pounds. Pulling it through the pipe was extremely difficult. Halfway through, the wire feeder came loose and we had to start over. Uncle Martin cut the top of the pipe at the 90 degree bend, and I threw everything at it, including the kitchen sink and the air fryer. Finally, it came through.
Ethernet, explained in about a minute
An ethernet cable is eight tiny wires in a trench coat: four pairs, each pair twisted. Those twists block interference, so keep them as close to the jack as you can.
- Strip about two inches of the outer jacket. If you nick the little wires, cut it off and start over. Ask me how I know.
- Cut off the little white string. You don't need it.
- Use the B color chart on the keystone jack. Both ends of the cable have to match.
- Lay each wire in the slot with its color, then squeeze once with a keystone termination tool. It pushes all eight wires down and cuts the extra.
- Test it. The right way is a cable tester. I used an iPad at every jack. It worked, but an iPad can't tell you which wire is wrong. Get a tester.
Why the office gets its own access point
Our Wi-Fi lives in the house and the office lives in the yard. By the time the signal gets out here, it has one bar and a bad attitude. So the office got a NETGEAR WAX610 access point, powered over the same ethernet cable. Pro tip: give it the exact same name and password as your house Wi-Fi, and your phone hands you off as you walk out. Give it a different name and your phone hangs on to the house until it drops, which is a problem on an important Zoom call.
The wall plate
Behind the TV is a 12-port keystone wall plate: two HDMIs, one ethernet for low latency gaming (I mean work), four speakers, and five blank inserts. I paid money for nothing, five times. The mounting bracket is supposed to go on after the drywall, which explains why I struggled with it.
The lights that wouldn't turn on
We flipped the switch and the lights did not come on. The Lutron switch just blinked. We have 10 recessed lights. Uncle Martin, him, not me, ran the wire to fixtures 1 through 9 and forgot to connect the 10th. That left the circuit open, so none of the other 9 came on either. If your Lutron switch is blinking and you're running more than one light from it, make sure the circuit is fully closed.
The network gear is in Home Networking and Media Enclosure. Watch the whole fight with that cable on the video page or on YouTube.
As an Amazon Associate, CornerBuilt earns from qualifying purchases. Some links in this post are affiliate links, which may earn us a commission at no extra cost to you.